Repurpose telephone line to ethernetHow do I run ethernet cable through a wall cavity?How can I modify...

The logic of invoking virtual functions is not clear (or it is method hiding?)

Metal that glows when near pieces of itself

What is the hex versus octal timeline?

What is the improvement of the "legally binding commitment" proposed by Boris Johnson over the existing "backstop"?

Why does my house heat up, even when it's cool outside?

How to persuade recruiters to send me the Job Description?

Thread-safe, Convenient and Performant Random Number Generator

Is there a known non-euclidean geometry where two concentric circles of different radii can intersect? (as in the novel "The Universe Between")

Can others monetize my project with GPLv3?

Don't understand MOSFET as amplifier

Was this pillow joke on Friends intentional or a mistake?

Are required indicators necessary for radio buttons?

What is the difference between a premise and an assumption in logic?

Can pay be witheld for hours cleaning up after closing time?

Is it appropriate for a prospective landlord to ask me for my credit report?

Does Swashbuckler's Fancy Footwork apply if the attack was made with Booming Blade?

Dark side of an exoplanet - if it was earth-like would its surface light be detectable?

Are thrust levers synchronized by default when pushed/pulled?

Shouldn't the "credit score" prevent Americans from going deeper and deeper into personal debt?

What is "Wayfinder's Guide to Eberron"?

To "hit home" in German

How would one country purchase another?

In an emergency, how do I find and share my position?

How should I think about joining a company whose business I do not understand?



Repurpose telephone line to ethernet


How do I run ethernet cable through a wall cavity?How can I modify telephone Cat5 cables and jacks into Ethernet ports?Can I repurpose existing cat5 telephone line for Ethernet networking?Are there any disadvantages to switching from a punch-down distribution box to an RJ-45 one?Is my plan for wiring ethernet reasonable?Retrofit apartment for gigabit internetRe-wire Cat5e RJ11 jacks to RJ45 ethernetRunning a New Telephone Wire For Master Socket - Cross Over Electrical CablesWiring ethernet cable from AT&T fiber Modem to a specific room






.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty,.everyoneloves__bot-mid-leaderboard:empty{ margin-bottom:0;
}







20















I have a (UK) telephone socket in the same corner of each of the three floors in my house. My broadband router is connected to the socket on the bottom floor.
The wiring looks like the following:



Top floor:
enter image description here



Middle floor:
enter image description here



Bottom floor:
enter image description hereenter image description here



What type of cable is it? Can I use it for ethernet? If not, would it be pretty straightforward to run an ethernet cable alongside it?










share|improve this question









New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.

















  • 3





    Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

    – Criggie
    2 days ago













  • You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

    – Criggie
    2 days ago








  • 6





    @Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

    – alephzero
    2 days ago








  • 2





    ... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

    – alephzero
    2 days ago


















20















I have a (UK) telephone socket in the same corner of each of the three floors in my house. My broadband router is connected to the socket on the bottom floor.
The wiring looks like the following:



Top floor:
enter image description here



Middle floor:
enter image description here



Bottom floor:
enter image description hereenter image description here



What type of cable is it? Can I use it for ethernet? If not, would it be pretty straightforward to run an ethernet cable alongside it?










share|improve this question









New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.

















  • 3





    Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

    – Criggie
    2 days ago













  • You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

    – Criggie
    2 days ago








  • 6





    @Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

    – alephzero
    2 days ago








  • 2





    ... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

    – alephzero
    2 days ago














20












20








20


2






I have a (UK) telephone socket in the same corner of each of the three floors in my house. My broadband router is connected to the socket on the bottom floor.
The wiring looks like the following:



Top floor:
enter image description here



Middle floor:
enter image description here



Bottom floor:
enter image description hereenter image description here



What type of cable is it? Can I use it for ethernet? If not, would it be pretty straightforward to run an ethernet cable alongside it?










share|improve this question









New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











I have a (UK) telephone socket in the same corner of each of the three floors in my house. My broadband router is connected to the socket on the bottom floor.
The wiring looks like the following:



Top floor:
enter image description here



Middle floor:
enter image description here



Bottom floor:
enter image description hereenter image description here



What type of cable is it? Can I use it for ethernet? If not, would it be pretty straightforward to run an ethernet cable alongside it?







wiring data-wiring ethernet telephone






share|improve this question









New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.










share|improve this question









New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.








share|improve this question




share|improve this question








edited 2 days ago







gozzilli













New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.








asked 2 days ago









gozzilligozzilli

2031 silver badge6 bronze badges




2031 silver badge6 bronze badges




New contributor



gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.




New contributor




gozzilli is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.













  • 3





    Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

    – Criggie
    2 days ago













  • You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

    – Criggie
    2 days ago








  • 6





    @Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

    – alephzero
    2 days ago








  • 2





    ... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

    – alephzero
    2 days ago














  • 3





    Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

    – Criggie
    2 days ago













  • You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

    – Criggie
    2 days ago








  • 6





    @Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

    – alephzero
    2 days ago








  • 2





    ... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

    – alephzero
    2 days ago








3




3





Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

– Criggie
2 days ago







Can you unscrew the box from the wall, and pull some of the slack cable out? The writing on the side will tell you exactly what cable it is. Also count the number of wires (or number of pairs) in the cable - I see 6 wire/3 pair.

– Criggie
2 days ago















You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

– Criggie
2 days ago







You're in the UK - are you permitted to change the house phone wiring now? I know in the bad old days you could not change internal phone wiring, only BT could do that.

– Criggie
2 days ago






6




6





@Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

– alephzero
2 days ago







@Criggie on a modern BT domestic installation, there will be a single NTE5 socket somewhere (not the same as the OP's "master socket 5C" pictures). NTE = "Network termination equipment." That is the point where BT responsibility for the wiring ends. The NTE socket provides a clean way to disconnect the rest of the wiring, and a test point for BT, by removing the front panel (fixed by screws) which internally plugs into the termination of the BT wiring. With the front removed, there is a standard phone socket inside which can be used to check if faults are in the house wiring or the BT network.

– alephzero
2 days ago






2




2





... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

– alephzero
2 days ago





... i.e. if you take the front panel off the NTE5, plug a phone into the internal socket, and it works, there is "nothing wrong with the BT wiring" and you are on your own for fixing other problems.

– alephzero
2 days ago










3 Answers
3






active

oldest

votes


















20














Gigabit Ethernet



If you need Gigabit Ethernet (1000Base-T), you're out of luck and will have to run new wires with CAT 5e or better cabling. It's likely not that difficult depending on your house. It seems like these jacks are above each other in the same place on each floor. Thus, you could easily drop a cable down from the upper floor and run them all down to your bottom floor. If the cables are in different spots, it'll be more challenging. However, you could just cut a small hole in your wall and then you'll need to cut another small hole in your frame using a bit like this. It's not as bad as it seems - especially if there's already a wire you follow (ie: your telephone line).



Fast Ethernet (100 Mb/s)



If you're only interested in Fast Ethernet (100Base-TX, ubiquitous), you can rewire those telephone lines to become ethernet lines without much work, provided the existing cables are CAT 5 or better. Check the outer sheath of the cable to determine what you have. If it is only CAT 3 then you are out of luck. You'll have to make a few concessions for that to work:




  • You'll have to have a switch on your middle floor

  • You're giving up your telephone lines (as they will be ethernet instead


The telephone wires in your house have 3 twisted pairs. Ethernet is usually ran with 4 twisted pair wires. However, for 100Base-TX, 2 of those twisted pair wires aren't used as only the orange and green are used for transmit and receive. The blue wires are used for Power Over Ethernet. From your pictures, you should be able to wire a RJ-45 Keystone Jack with all 3 pairs of your wire.



Cat5e Wiring Diagram



Basically, you'll need to take your orange, green, and blue wires and connect them to the terminal on your RJ-45 jack on each floor. On the middle floor, where you have 2 wires, you'll need 2 keystone jacks. Then, you'll need to put an ethernet switch in the middle floor and connect both the top and bottom floor (along with the middle floor). If you're only interested in connected the top and bottom floor, you can put in a small 6" patch cable to connect the top and bottom floors together. Obviously, you'll need to remove your telephone jacks to replace them with the RJ45 keystone jacks mentioned previously. While this solution isn't the fastest, it take minimum effort to get up and running.






share|improve this answer










New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.

















  • 1





    Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

    – gozzilli
    2 days ago






  • 2





    "If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

    – marcelm
    2 days ago








  • 4





    They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

    – technogeek1995
    2 days ago








  • 4





    "you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

    – Martin Bonner
    yesterday






  • 2





    Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

    – mirabilos
    yesterday



















6














The cable type is almost certainly BT spec CW1308, 3 pairs would be normal for UK extension wiring.



It won't be to Cat5 or better spec, but over a short run and without external interference you will probably get 10Mbits over it, maybe even 100Mbits.






share|improve this answer























  • 3





    Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

    – manassehkatz
    2 days ago






  • 4





    @manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

    – a CVn
    2 days ago






  • 2





    CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

    – psmears
    yesterday



















3














I would inspect to see if the telephone cable is run in some type of conduit, but in UK that, sadly, is not always the case.



If you are lucky and it is in a conduit then I would use a cable puller and run cat 6 cable up to each floor.



If you are not lucky, then you could take the risk of disconnecting the telephone cable and using that to pull through two lines. One to put back the telephone cable and one to pull the cat 6 through.






share|improve this answer





















  • 1





    ...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

    – Ilmari Karonen
    yesterday






  • 2





    If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

    – bta
    yesterday














Your Answer








StackExchange.ready(function() {
var channelOptions = {
tags: "".split(" "),
id: "73"
};
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function() {
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled) {
StackExchange.using("snippets", function() {
createEditor();
});
}
else {
createEditor();
}
});

function createEditor() {
StackExchange.prepareEditor({
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader: {
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
},
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
});


}
});






gozzilli is a new contributor. Be nice, and check out our Code of Conduct.










draft saved

draft discarded


















StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f171512%2frepurpose-telephone-line-to-ethernet%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown

























3 Answers
3






active

oldest

votes








3 Answers
3






active

oldest

votes









active

oldest

votes






active

oldest

votes









20














Gigabit Ethernet



If you need Gigabit Ethernet (1000Base-T), you're out of luck and will have to run new wires with CAT 5e or better cabling. It's likely not that difficult depending on your house. It seems like these jacks are above each other in the same place on each floor. Thus, you could easily drop a cable down from the upper floor and run them all down to your bottom floor. If the cables are in different spots, it'll be more challenging. However, you could just cut a small hole in your wall and then you'll need to cut another small hole in your frame using a bit like this. It's not as bad as it seems - especially if there's already a wire you follow (ie: your telephone line).



Fast Ethernet (100 Mb/s)



If you're only interested in Fast Ethernet (100Base-TX, ubiquitous), you can rewire those telephone lines to become ethernet lines without much work, provided the existing cables are CAT 5 or better. Check the outer sheath of the cable to determine what you have. If it is only CAT 3 then you are out of luck. You'll have to make a few concessions for that to work:




  • You'll have to have a switch on your middle floor

  • You're giving up your telephone lines (as they will be ethernet instead


The telephone wires in your house have 3 twisted pairs. Ethernet is usually ran with 4 twisted pair wires. However, for 100Base-TX, 2 of those twisted pair wires aren't used as only the orange and green are used for transmit and receive. The blue wires are used for Power Over Ethernet. From your pictures, you should be able to wire a RJ-45 Keystone Jack with all 3 pairs of your wire.



Cat5e Wiring Diagram



Basically, you'll need to take your orange, green, and blue wires and connect them to the terminal on your RJ-45 jack on each floor. On the middle floor, where you have 2 wires, you'll need 2 keystone jacks. Then, you'll need to put an ethernet switch in the middle floor and connect both the top and bottom floor (along with the middle floor). If you're only interested in connected the top and bottom floor, you can put in a small 6" patch cable to connect the top and bottom floors together. Obviously, you'll need to remove your telephone jacks to replace them with the RJ45 keystone jacks mentioned previously. While this solution isn't the fastest, it take minimum effort to get up and running.






share|improve this answer










New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.

















  • 1





    Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

    – gozzilli
    2 days ago






  • 2





    "If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

    – marcelm
    2 days ago








  • 4





    They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

    – technogeek1995
    2 days ago








  • 4





    "you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

    – Martin Bonner
    yesterday






  • 2





    Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

    – mirabilos
    yesterday
















20














Gigabit Ethernet



If you need Gigabit Ethernet (1000Base-T), you're out of luck and will have to run new wires with CAT 5e or better cabling. It's likely not that difficult depending on your house. It seems like these jacks are above each other in the same place on each floor. Thus, you could easily drop a cable down from the upper floor and run them all down to your bottom floor. If the cables are in different spots, it'll be more challenging. However, you could just cut a small hole in your wall and then you'll need to cut another small hole in your frame using a bit like this. It's not as bad as it seems - especially if there's already a wire you follow (ie: your telephone line).



Fast Ethernet (100 Mb/s)



If you're only interested in Fast Ethernet (100Base-TX, ubiquitous), you can rewire those telephone lines to become ethernet lines without much work, provided the existing cables are CAT 5 or better. Check the outer sheath of the cable to determine what you have. If it is only CAT 3 then you are out of luck. You'll have to make a few concessions for that to work:




  • You'll have to have a switch on your middle floor

  • You're giving up your telephone lines (as they will be ethernet instead


The telephone wires in your house have 3 twisted pairs. Ethernet is usually ran with 4 twisted pair wires. However, for 100Base-TX, 2 of those twisted pair wires aren't used as only the orange and green are used for transmit and receive. The blue wires are used for Power Over Ethernet. From your pictures, you should be able to wire a RJ-45 Keystone Jack with all 3 pairs of your wire.



Cat5e Wiring Diagram



Basically, you'll need to take your orange, green, and blue wires and connect them to the terminal on your RJ-45 jack on each floor. On the middle floor, where you have 2 wires, you'll need 2 keystone jacks. Then, you'll need to put an ethernet switch in the middle floor and connect both the top and bottom floor (along with the middle floor). If you're only interested in connected the top and bottom floor, you can put in a small 6" patch cable to connect the top and bottom floors together. Obviously, you'll need to remove your telephone jacks to replace them with the RJ45 keystone jacks mentioned previously. While this solution isn't the fastest, it take minimum effort to get up and running.






share|improve this answer










New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.

















  • 1





    Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

    – gozzilli
    2 days ago






  • 2





    "If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

    – marcelm
    2 days ago








  • 4





    They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

    – technogeek1995
    2 days ago








  • 4





    "you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

    – Martin Bonner
    yesterday






  • 2





    Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

    – mirabilos
    yesterday














20












20








20







Gigabit Ethernet



If you need Gigabit Ethernet (1000Base-T), you're out of luck and will have to run new wires with CAT 5e or better cabling. It's likely not that difficult depending on your house. It seems like these jacks are above each other in the same place on each floor. Thus, you could easily drop a cable down from the upper floor and run them all down to your bottom floor. If the cables are in different spots, it'll be more challenging. However, you could just cut a small hole in your wall and then you'll need to cut another small hole in your frame using a bit like this. It's not as bad as it seems - especially if there's already a wire you follow (ie: your telephone line).



Fast Ethernet (100 Mb/s)



If you're only interested in Fast Ethernet (100Base-TX, ubiquitous), you can rewire those telephone lines to become ethernet lines without much work, provided the existing cables are CAT 5 or better. Check the outer sheath of the cable to determine what you have. If it is only CAT 3 then you are out of luck. You'll have to make a few concessions for that to work:




  • You'll have to have a switch on your middle floor

  • You're giving up your telephone lines (as they will be ethernet instead


The telephone wires in your house have 3 twisted pairs. Ethernet is usually ran with 4 twisted pair wires. However, for 100Base-TX, 2 of those twisted pair wires aren't used as only the orange and green are used for transmit and receive. The blue wires are used for Power Over Ethernet. From your pictures, you should be able to wire a RJ-45 Keystone Jack with all 3 pairs of your wire.



Cat5e Wiring Diagram



Basically, you'll need to take your orange, green, and blue wires and connect them to the terminal on your RJ-45 jack on each floor. On the middle floor, where you have 2 wires, you'll need 2 keystone jacks. Then, you'll need to put an ethernet switch in the middle floor and connect both the top and bottom floor (along with the middle floor). If you're only interested in connected the top and bottom floor, you can put in a small 6" patch cable to connect the top and bottom floors together. Obviously, you'll need to remove your telephone jacks to replace them with the RJ45 keystone jacks mentioned previously. While this solution isn't the fastest, it take minimum effort to get up and running.






share|improve this answer










New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.









Gigabit Ethernet



If you need Gigabit Ethernet (1000Base-T), you're out of luck and will have to run new wires with CAT 5e or better cabling. It's likely not that difficult depending on your house. It seems like these jacks are above each other in the same place on each floor. Thus, you could easily drop a cable down from the upper floor and run them all down to your bottom floor. If the cables are in different spots, it'll be more challenging. However, you could just cut a small hole in your wall and then you'll need to cut another small hole in your frame using a bit like this. It's not as bad as it seems - especially if there's already a wire you follow (ie: your telephone line).



Fast Ethernet (100 Mb/s)



If you're only interested in Fast Ethernet (100Base-TX, ubiquitous), you can rewire those telephone lines to become ethernet lines without much work, provided the existing cables are CAT 5 or better. Check the outer sheath of the cable to determine what you have. If it is only CAT 3 then you are out of luck. You'll have to make a few concessions for that to work:




  • You'll have to have a switch on your middle floor

  • You're giving up your telephone lines (as they will be ethernet instead


The telephone wires in your house have 3 twisted pairs. Ethernet is usually ran with 4 twisted pair wires. However, for 100Base-TX, 2 of those twisted pair wires aren't used as only the orange and green are used for transmit and receive. The blue wires are used for Power Over Ethernet. From your pictures, you should be able to wire a RJ-45 Keystone Jack with all 3 pairs of your wire.



Cat5e Wiring Diagram



Basically, you'll need to take your orange, green, and blue wires and connect them to the terminal on your RJ-45 jack on each floor. On the middle floor, where you have 2 wires, you'll need 2 keystone jacks. Then, you'll need to put an ethernet switch in the middle floor and connect both the top and bottom floor (along with the middle floor). If you're only interested in connected the top and bottom floor, you can put in a small 6" patch cable to connect the top and bottom floors together. Obviously, you'll need to remove your telephone jacks to replace them with the RJ45 keystone jacks mentioned previously. While this solution isn't the fastest, it take minimum effort to get up and running.







share|improve this answer










New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.








share|improve this answer



share|improve this answer








edited yesterday









ilkkachu

1052 bronze badges




1052 bronze badges






New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.








answered 2 days ago









technogeek1995technogeek1995

3389 bronze badges




3389 bronze badges




New contributor



technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.




New contributor




technogeek1995 is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.













  • 1





    Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

    – gozzilli
    2 days ago






  • 2





    "If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

    – marcelm
    2 days ago








  • 4





    They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

    – technogeek1995
    2 days ago








  • 4





    "you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

    – Martin Bonner
    yesterday






  • 2





    Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

    – mirabilos
    yesterday














  • 1





    Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

    – gozzilli
    2 days ago






  • 2





    "If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

    – marcelm
    2 days ago








  • 4





    They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

    – technogeek1995
    2 days ago








  • 4





    "you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

    – Martin Bonner
    yesterday






  • 2





    Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

    – mirabilos
    yesterday








1




1





Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

– gozzilli
2 days ago





Stellar answer, thanks @technogeek1995. The wires in the middle floor seem to be connected together on the plate, can I just leave them as they are (to achieve Base100T connection bottom to top, skipping middle)?

– gozzilli
2 days ago




2




2





"If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

– marcelm
2 days ago







"If you need to Base1000T, you're out of luck and will have to run new wires with CAT6 cabling." - CAT5 is adequate for 1000BASE-T, so if the existing wiring is 4-pair / 8-wire CAT5 (doesn't look like it though), he doesn't need to replace it.

– marcelm
2 days ago






4




4





They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

– technogeek1995
2 days ago







They don’t need to be foiled or shielded at it’s a digital transmission. Being twisted pairs is the most critical to prevent interference, but I can’t tell from the pictures. However, judging by the cable, I don’t think it’s likely they aren’t twisted pairs. Even 4 wire phone lines should be twisted pair.

– technogeek1995
2 days ago






4




4





"you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

– Martin Bonner
yesterday





"you'll need to cut another small hole in your frame" - this is the UK. If this is an outside wall, it is almost certainly a brick or block wall, not a wood frame.

– Martin Bonner
yesterday




2




2





Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

– mirabilos
yesterday





Cat3 (often used in in-house ISDN lines) is usually enough for 100baseTX. The OP doesn’t need to wire up all three line pairs, just two of them, but the how is important (to keep the pairs twisted inside the cable matching the connector pins correctly).

– mirabilos
yesterday













6














The cable type is almost certainly BT spec CW1308, 3 pairs would be normal for UK extension wiring.



It won't be to Cat5 or better spec, but over a short run and without external interference you will probably get 10Mbits over it, maybe even 100Mbits.






share|improve this answer























  • 3





    Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

    – manassehkatz
    2 days ago






  • 4





    @manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

    – a CVn
    2 days ago






  • 2





    CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

    – psmears
    yesterday
















6














The cable type is almost certainly BT spec CW1308, 3 pairs would be normal for UK extension wiring.



It won't be to Cat5 or better spec, but over a short run and without external interference you will probably get 10Mbits over it, maybe even 100Mbits.






share|improve this answer























  • 3





    Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

    – manassehkatz
    2 days ago






  • 4





    @manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

    – a CVn
    2 days ago






  • 2





    CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

    – psmears
    yesterday














6












6








6







The cable type is almost certainly BT spec CW1308, 3 pairs would be normal for UK extension wiring.



It won't be to Cat5 or better spec, but over a short run and without external interference you will probably get 10Mbits over it, maybe even 100Mbits.






share|improve this answer















The cable type is almost certainly BT spec CW1308, 3 pairs would be normal for UK extension wiring.



It won't be to Cat5 or better spec, but over a short run and without external interference you will probably get 10Mbits over it, maybe even 100Mbits.







share|improve this answer














share|improve this answer



share|improve this answer








edited 11 hours ago









user11153

1051 silver badge5 bronze badges




1051 silver badge5 bronze badges










answered 2 days ago









OwainOwain

9451 silver badge7 bronze badges




9451 silver badge7 bronze badges











  • 3





    Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

    – manassehkatz
    2 days ago






  • 4





    @manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

    – a CVn
    2 days ago






  • 2





    CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

    – psmears
    yesterday














  • 3





    Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

    – manassehkatz
    2 days ago






  • 4





    @manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

    – a CVn
    2 days ago






  • 2





    CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

    – psmears
    yesterday








3




3





Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

– manassehkatz
2 days ago





Cat3 (or similar) for 100 MB is often a big problem. If you can force it to 10 MB then it is great - and plenty fast enough for a lot of uses. But if you can't force it to 10 MB then it might bounce between 10 & 100 or run at 100 but with a lot of errors which can slow things down to worse than 10 MB. Easy fix would be a 10 MB switch in the middle location - if you can find one.

– manassehkatz
2 days ago




4




4





@manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

– a CVn
2 days ago





@manassehkatz If the network card can do 10 Mbit/s in the first place, then there's usually a way to set it via software to force it to use only 10 Mbit/s, rather than to autosense the speed. Beware, both ends have to have the same setting or it won't work.

– a CVn
2 days ago




2




2





CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

– psmears
yesterday





CW1308 is basically CAT3, and CAT3 is sufficient for 10BASET, so you should indeed be able to get 10MBps over it, even over relatively long runs :)

– psmears
yesterday











3














I would inspect to see if the telephone cable is run in some type of conduit, but in UK that, sadly, is not always the case.



If you are lucky and it is in a conduit then I would use a cable puller and run cat 6 cable up to each floor.



If you are not lucky, then you could take the risk of disconnecting the telephone cable and using that to pull through two lines. One to put back the telephone cable and one to pull the cat 6 through.






share|improve this answer





















  • 1





    ...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

    – Ilmari Karonen
    yesterday






  • 2





    If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

    – bta
    yesterday
















3














I would inspect to see if the telephone cable is run in some type of conduit, but in UK that, sadly, is not always the case.



If you are lucky and it is in a conduit then I would use a cable puller and run cat 6 cable up to each floor.



If you are not lucky, then you could take the risk of disconnecting the telephone cable and using that to pull through two lines. One to put back the telephone cable and one to pull the cat 6 through.






share|improve this answer





















  • 1





    ...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

    – Ilmari Karonen
    yesterday






  • 2





    If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

    – bta
    yesterday














3












3








3







I would inspect to see if the telephone cable is run in some type of conduit, but in UK that, sadly, is not always the case.



If you are lucky and it is in a conduit then I would use a cable puller and run cat 6 cable up to each floor.



If you are not lucky, then you could take the risk of disconnecting the telephone cable and using that to pull through two lines. One to put back the telephone cable and one to pull the cat 6 through.






share|improve this answer













I would inspect to see if the telephone cable is run in some type of conduit, but in UK that, sadly, is not always the case.



If you are lucky and it is in a conduit then I would use a cable puller and run cat 6 cable up to each floor.



If you are not lucky, then you could take the risk of disconnecting the telephone cable and using that to pull through two lines. One to put back the telephone cable and one to pull the cat 6 through.







share|improve this answer












share|improve this answer



share|improve this answer










answered 2 days ago









Solar MikeSolar Mike

5,3771 gold badge5 silver badges17 bronze badges




5,3771 gold badge5 silver badges17 bronze badges











  • 1





    ...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

    – Ilmari Karonen
    yesterday






  • 2





    If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

    – bta
    yesterday














  • 1





    ...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

    – Ilmari Karonen
    yesterday






  • 2





    If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

    – bta
    yesterday








1




1





...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

– Ilmari Karonen
yesterday





...or, presumably, just pull the cat6 through and recycle the old phone cable. There's really not much use for it nowadays.

– Ilmari Karonen
yesterday




2




2





If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

– bta
yesterday





If you want to keep the phone line without pulling up a second wire, tie a long string to the top end of the cat 6 before you pull it through. Later, you can untie it, tie it to the end of the phone cable, and use it to pull the phone cable back down through the wall where it originally was.

– bta
yesterday










gozzilli is a new contributor. Be nice, and check out our Code of Conduct.










draft saved

draft discarded


















gozzilli is a new contributor. Be nice, and check out our Code of Conduct.













gozzilli is a new contributor. Be nice, and check out our Code of Conduct.












gozzilli is a new contributor. Be nice, and check out our Code of Conduct.
















Thanks for contributing an answer to Home Improvement Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid



  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.


To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f171512%2frepurpose-telephone-line-to-ethernet%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown







Popular posts from this blog

Taj Mahal Inhaltsverzeichnis Aufbau | Geschichte | 350-Jahr-Feier | Heutige Bedeutung | Siehe auch |...

Baia Sprie Cuprins Etimologie | Istorie | Demografie | Politică și administrație | Arii naturale...

Nicolae Petrescu-Găină Cuprins Biografie | Opera | In memoriam | Varia | Controverse, incertitudini...